Rubber dam placement in real time

12 min

From clamp selection to inversion, uncut, with the moments where it usually goes wrong.

About this video

Placement from the clamp to the inverted margin, uncut. The two moments where a dam usually fails — a clamp that rocks, a hole punched too close to its neighbour — are shown and corrected.

Speakers

Prof. Dr. Julia Janssen

More videos with Prof. Dr. Julia Janssen

A workflow you can take back to the practice on Monday.